Hot search: handbag  banner  curtain  coat  leather  crystal  cape  shorts  scarf  backdrop 
 

BASE850 Ventilator With Compressor

Click on the image to check the artwork
unit price: negotiable
min amount:
amount:
period for delivery: Consignment Deadline Days
area: Beijing
Expiry date : Long Effective
last update: 2017-07-01 14:20
view count: 63
enquiry
Company Profile
 
 
Product details
 12.1 inch TFT color screen , big screen could show more information.
 Screen could be rotated freely, suitable to operate in any angle and height
 With heater device to prevent water into ventilator
 Could show Paw-t、Flow-t、Volume-t、Paw-V、Flow-V five waveform at the same time, also could show one or several waveform according to our operation.
 Curve size ,time scale, pressure-flow ratio adjustable, watch the details more good.
 Curve pause function, could watch details.
 Flow, pressure two trigger function, could effect at a same time.
 Automatically inspiratory synchronous nebulizing function, nebulizing time adjustable;
 100% Oxygen inspiratory function, oxygen inspiratory time is adjustable.
 High, medium, low- grade alarm function;
 Alarm record functions, could record the last 100 pieces of information, show alarm grade, alarm time and the alarm parameter.
 Pressure, volume, time respiratory mode security, could inspect pressure in inspiratory phase, volume, time exceed the regulated value, turn into expiratory, ensure patient safety.
 Volume security function, keep the minimum tidal volume in pressure mode.
 Adjust MMV function automatic, adjust inspiratory pressure and breathing frequency, approaching the target tidal volume and minute ventilator.
 VGA connector could output the screen signal to other screen

Specification

Operating Modes
Volume Control Ventilation (VCV)
Assisted/Controlled Pressure Control Ventilation (PCV),
Assisted/Controlled Pressure Support Ventilation (PSV),
SIMV(VCV)+PSV
SIMV(PCV)+PSV
Mandatory Minute Ventilation (MMV)
Continuous Positive Airway Pressure(CPAP)
Backup Apnea Ventilation

Parameter
Application scope: Pediatric and adult
Driven mode: Pneumatically driven and electronically controlled
Display:12.1 TFT screen
Working mode: Pressure and volume
Ventilation wave type: Squire wave, deceleration wave
FiO2: 21% to 100%
PEEP/CPAP: 0 to 40 cmH2O
Inspiratory Sensitivity:
Flow triggered: 0.5 to 20 L/min, OFF
Pressure triggered: -1 to -20 cmH2O, OFF
Tidal Volume: 20 to 2000 mL
Breath frequency: 1 to 100 bpm
I:E Ratio: 5.0 : 1 to 1 : 5.0
Inspiratory plateau: 0 to 50%
Inspiratory Flow Wave Shape(VCV): Rectangular wave and Decelerating wave
SIGH: 1.0 to 2.0
Breath frequency(SIMV): 2 to 40bpm
Inspiratory time (SIMV): 0.1 to 12 S
Pressure Support Ventilation (PSV): 0 to 40 cmH2O
Expiratory Sensitivity for PSV : 10% to 75% of the initial flow
Maximum Inspiratory time (PSV): 1.0 to 8.0 S
Pressure Control Ventilation(PCV): 0 to 40 cmH2O
Minimum Tidal Volume(PCV and PSV): 50 to 1500 mL
Backup Rate (PSV): 2 to 40 bpm
Object Tidal Volume(MMV): 20 to 2000 mL
Ventilation volume(MMV): 0.5 to 40.0 L/min
Nebulizer time: 30 minutes
Total0bar [View All]  Related Comments
 
More>other products

[ ProductsSearch ]  [ Send Fav ]  [ Share ]  [ Print ]  [ Send Report ]  [ Close ]

 